Advanced microprocessor and communication technology, simple hardware structure, strong anti-interference performance, stable operation and reliable performance; It can support up to 4 outputs, flexible configuration and easy to use; Dot matrix LCD screen, Chinese menu, simple and intuitive operation; Strong versatility, supports various gas detectors using three-wire 4~20mA current signal or RS485 digital signal; Up to 6 passive switches, which can be freely controlled by partition; Standard RS485 upload interface, can upload DCS and PLC systems and computer host; support data storage function and query function; wall-mounted installation, flexible and simple installation.
Advanced microprocessor and communication technology, simple hardware structure, strong anti-interference performance, stable operation, reliable performance,
can support 4-channel, 8-channel, 16-channel output, flexible configuration, easy to use
dot matrix LCD screen, Chinese menu, operation Simple and intuitive
Strong versatility, supports various gas detectors using three-wire 4-20mA current signal or RS485 digital signal
Up to 6 passive switches, which can be controlled freely in zones
Supports two-stage sound and light alarm, and the alarm point can be set arbitrarily
Standard RS485 upload interface, can upload DCS, PLC system and computer host
Support data storage function and query function, alarm record can be checked, and record the highest concentration value of the alarm
Wall-mounted installation, flexible and simple installation
Advanced Microprocessor Technology
Simple hardware architecture, strong anti-interference performance, stable operation and reliable performance;
Support a variety of signal input and output modes
Strong versatility, can accept 4-20mA current signal or RS485 bus input, with relay switch output;
Flexible expansion, strong versatility,
Can support 4, 8 and 16 outputs, flexible configuration and easy to use;
Dot matrix LCD screen, Chinese menu
Dot matrix LCD screen, Chinese menu, simple and intuitive operation;
Technical parameter
name | parameter value |
detect gas | flammable/toxic gas |
signal input | Three-wire 4-20mA or RS485 |
Accuracy | ±3% FS |
Repeatability | <2% |
Response time | <5S |
Display method | Dot matrix LCD screen, Chinese menu |
Alarm method | Two-stage sound and light alarm, sound ≥80dB@30cm |
Alarm system | Alarm points can be set arbitrarily |
output signal | Up to 6 passive switches, which can be freely controlled by partition; RS485 signal |
output power | Each channel provides 24~28VDC, 200mA |
load capacity | <5W per channel |
Working power | 220VAC/50Hz |
ambient temperature | 0℃ ~ +40℃ |
environment humidity | 15~95%RH/No condensation |
Installation method | Wall-mounted |
Dimensions | 270×350×75mm (WxHxD) |
weight | 2500 grams |
System connection diagram