Falcon550-PRO Series Portable Multi-Gas Detector

Up to 5 different gases can be measured; imported industrial-grade sensors, typical response time T90<15 seconds; alarm volume greater than 95dB@30cm; continuous working time over 36 hours on a single charge; protection grade IP67, explosion-proof grade IICT4; robust and durable, expected The service life is more than 3 years.

 

 

 

 

The Falcon550-PRO series of portable multi-gas detectors independently developed by Xinzhi Sensing can measure 1-5 kinds of combustible and toxic gases at the same time;
using imported industrial-grade sensors, the typical response time is T90<15 seconds ;
continuous working time for one charge More than 36 hours ;
the alarm volume is greater than 95dB@30cm ;
the protection level is IP67 , and the explosion-proof level is ExdibIICT4 ;
it is durable and has an expected service life of more than 3 years ;
it supports sensors with different principles such as catalytic combustion, electrochemistry, infrared absorption, and photoionization.

Excellent detection performance
Imported industrial-grade sensors and fast sampling technology are used, which are sensitive in detection and fast in response. Most gases can achieve a response time of T90<15s. At the same time, the life of the sensor is more than 2 years; using the new intelligent Stand-by quick start technology, the whole machine start-up warm-up time is less than 5 seconds; using a special catalytic combustion sensor (with independent explosion-proof certification), it has ultra-low power consumption and shock resistance , anti-H2S poisoning, anti-silicon poisoning and other superior characteristics
Meet industrial-grade harsh environment requirements
​​​Intrinsically safe design, explosion-proof grade up to IICT4, protection grade up to IP67, waterproof, dust-proof, anti-static, meeting the strict requirements of industrial places; the shell is made of polyester rubber + PC composite structure, with excellent protection ability, with The special anti-shock sensor makes the whole machine have good anti-drop performance; the work is reliable, sturdy and durable, and the expected service life is more than 3 years;
A variety of alarm methods, comprehensive security
​​​At the same time, it supports three alarm modes of sound, light and vibration. Even in complex industrial site environment, it can effectively warn users and comprehensively ensure safety; the alarm volume is greater than 95dB@30cm, which can still be used in the noisy environment of industrial sites. Effective alarm; 360-degree bright LED alarm light;
Long working hours
​​Using high-performance lithium battery, combined with low-power intrinsically safe circuit design, the continuous working time of one charge is up to 36 hours; using fast charging technology that meets the requirements of intrinsically safe explosion-proof, the charging time is less than 5 hours; using long-life lithium battery, 300 times of charge and discharge performance decay <25%, battery life is more than 5 years;
Flexible configuration to meet diverse needs
​​​Supports simultaneous detection of 1-5 gases, and can flexibly configure a variety of sensors as needed to meet the diverse needs of users in different fields; supports sensors with different principles such as catalytic combustion, electrochemistry, infrared absorption, and photoionization ;Support chlorine, acrylonitrile, hydrogen fluoride, methyl mercaptan, benzene, formaldehyde and other special gas detection;
Powerful data storage and analysis functions
​​​Built-in large-capacity flash memory chip, which can store more than 100,000 event records; using an integrated USB charging/data transmission interface, data can be easily uploaded to a personal computer (PC) through the USB port; with a complete PC terminal Data analysis and processing software, which can present data records in multi-dimensional charts, and conduct statistics and analysis on historical data trends;

Technical parameter

name parameter value
weight 275 grams (including standard 4 sensors, battery, back clip)
size 115x72x34mm (LxWxH, without back clip)
Alarm indication Four alarm indicator lights, one buzzer, one vibration motor
Alarm volume >95dB@30cm
show 2.2 inch dot matrix LCD screen
Battery Type 3.7V rechargeable lithium battery (cannot be charged in explosion hazard area)
operating hours >36 hours (at room temperature of 25°C, with 4 sensors as standard)
charging time <5 hours (room temperature 25°C)
Preheat time 5 seconds
Operating temperature -30℃ to 60℃
Humidity range 5%-95%RH, no condensation
Explosion-proof grade Ex d ib IIC T4 Gb (with combustible gas sensor)
Protection class IP67
life expectancy more than 3 years

Standard four-gas configuration

gas name molecular formula Detection range Resolution Alarm point setting
flammable gas CC 0 – 100% LEL 1%LEL AL:25%LEL, AH:50%LEL
hydrogen sulfide H2S 0 – 100PPM 0.1PPM AL: 7PPM, AH: 15PPM
carbon monoxide CO 0 – 1000PPM 1PPM AL: 25PPM, AH: 100PPM
oxygen O2 0 – 30%VOL 0.1%VOL AL:19.5%VOL, AH:23%VOL

Other supported gases and ranges

gas name molecular formula Detection range Resolution
hydrogen sulfide H2S 0 – 20/30/50/100PPM 0.1PPM
carbon monoxide CO 0 – 50/100/200/500/1000ppm 1PPM
Chlorine Cl2 0 – 10PPM 0.01PPM
Ammonia NH3 0 – 50/100/500PPM 1PPM
oxygen O2 0 – 25/30%vol 0.1%vol
hydrogen H2 0 – 1000/2000PPM 1PPM
ethylene oxide C2H4O 0 – 100ppm 1PPM
ozone O3 0 – 1ppm 0.01PPM
sulfur dioxide SO2 0 – 30/100ppm 0.1PPM
vinyl chloride C2H3Cl 0 – 100ppm 1PPM
Hydrogen chloride HCl 0 – 30ppm 0.1PPM
hydrogen cyanide HCN 0 – 10/30/50ppm 0.1PPM
carbon dioxide CO2 0 – 5000/10000/20000PPM
0 – 5/10/20%VOL
1PPM
0.1%VOL
Acrylonitrile C3H3N 0 – 100ppm 1PPM
Tetrahydrothiophene C4H8S 0-30/50/100mg/m3 0.1mg/m3
*If you need to detect other gases or need other detection ranges, please contact us!