Falcon550-NH3 Portable Ammonia Gas Detector

Using imported industrial-grade sensors, it can accurately measure the concentration of ammonia gas in the air, the typical response time is T90<60 seconds; the alarm volume is greater than 95dB@30cm; the continuous working time exceeds 200 hours on a single charge; the protection level is IP67, and the explosion-proof level is IICT4; , the expected service life is more than 3 years.

 

 

 

 

The Falcon550 series of portable toxic gas detectors independently developed by Xinzhi Sensing can effectively detect oxygen, toxic gases and toxic volatile organic compound vapors (VOCs).
Imported industrial-grade sensors are used to detect sensitive and respond quickly. The continuous working time of one charge exceeds more than 200 hours (electrochemical sensor) ;
alarm volume is greater than 95dB@30cm ;
protection grade IP67 , explosion-proof grade ExibIICT4 ;
durable, expected service life is more than 3 years;
supports electrochemical, infrared absorption, photoionization and other sensors with different principles .

Excellent detection performance

Imported industrial-grade sensors are adopted, and fast sampling technology is adopted, which has sensitive detection and rapid response; adopts Xinzhi Stand-by fast startup technology, and the preheating time for most gases is less than 5 seconds;

Meet industrial-grade harsh environment requirements

​​​Intrinsically safe design, explosion-proof grade up to IICT4, protection grade up to IP67, waterproof, dust-proof, anti-static, meeting the strict requirements of industrial places; the shell is made of polyester rubber + PC composite structure, with excellent protection ability and good Excellent anti-drop performance; reliable work, expected service life is more than 3 years;

A variety of alarm methods, comprehensive security

​​​At the same time, it supports three alarm modes of sound, light and vibration. Even in complex industrial site environment, it can effectively warn users and comprehensively ensure safety; the alarm volume is greater than 95dB@30cm, which can still be used in the noisy environment of industrial sites. Effective alarm; 360-degree bright LED alarm light;

Long working hours

​​Using high-performance lithium battery, with low-power intrinsically safe circuit design, the continuous working time of one charge is up to 200 hours (electrochemical sensor); using fast charging technology that meets the requirements of intrinsically safe explosion-proof, the charging time is less than 5 hours; using Long-life lithium battery, 300 times of charge and discharge performance decay <25%, battery life is more than 5 years;

Flexible configuration to meet diverse needs

​​​Supports sensors with different principles such as electrochemistry, infrared absorption, photoionization, etc., which can be flexibly configured as needed to meet the diverse needs of users in different fields;

Powerful data storage and analysis functions

​​​Built-in large-capacity flash memory chip, which can store more than 100,000 event records; using an integrated USB charging/data transmission interface, data can be easily uploaded to a personal computer (PC) through the USB port; with a complete PC terminal Data analysis and processing software, which can present data records in multi-dimensional charts, and conduct statistics and analysis on historical data trends;

Technical parameter

name parameter value
weight 255 grams (including 1 electrochemical, battery, back clip)
size 115x72x34mm (LxWxH, without back clip)
Alarm indication Four alarm indicator lights, one buzzer, one vibration motor
Alarm volume >95dB@30cm
show 2.2 inch dot matrix LCD screen
Battery Type 3.7V rechargeable lithium battery (cannot be charged in explosion hazard area)
operating hours >200 hours (room temperature 25℃, electrochemical sensor)
charging time <5 hours (room temperature 25°C)
Preheat time 5 seconds
Operating temperature -30℃ to 60℃
Humidity range 5%-95%RH, no condensation
Explosion-proof grade Ex ib IIC T4 Gb (with combustible gas sensor)
Protection class IP67
life expectancy more than 3 years

List of common toxic gases

gas name molecular formula Detection range Resolution Response time Sensor life
hydrogen sulfide H2S 0 – 20/30/50/100PPM 0.1PPM 30s 2 years
carbon monoxide CO 0 – 50/100/200/500/1000ppm 1PPM 30s 2 years
Chlorine Cl2 0 – 10PPM 0.01PPM 60s 1 year
Ammonia NH3 0 – 50/100/500PPM 1PPM 60s 2 years
oxygen O2 0 – 25/30%vol 0.1%vol 20s 2 years
hydrogen H2 0 – 1000/2000PPM 1PPM 80s 2 years
ethylene oxide C2H4O 0 – 100ppm 1PPM 90s 2 years
ozone O3 0 – 1ppm 0.01PPM 60s 1 year
sulfur dioxide SO2 0 – 30/100ppm 0.1PPM 30s 2 years
vinyl chloride C2H3Cl 0 – 100ppm 1PPM 90s 2 years
Hydrogen chloride HCl 0 – 30ppm 0.1PPM 70s 2 years
hydrogen cyanide HCN 0 – 10/30/50ppm 0.1PPM 120s 2 years
carbon dioxide CO2 0 – 5000/10000/20000PPM
0 – 5/10/20%VOL
1PPM
0.1%VOL
30s 5 years
Acrylonitrile C3H3N 0 – 100ppm 1PPM 90s 2 years
Tetrahydrothiophene C4H8S 0-30/50/100mg/m3 0.1mg/m3 60s 2 years
*If you need to detect other gases or need other detection ranges, please contact us!